TY - GEN UR - http://lib.ugent.be/catalog/pug01:2940987 ID - pug01:2940987 LA - eng TI - Evaluation of image signal-to-noise ratio in time-of-flight PET PY - 2011 SN - 9781467301183 SN - 1082-3654 PB - Piscataway AU - Clementel, Enrico TW06 000070817575 AU - Vandenberghe, Stefaan TW06 801001340071 0000-0002-2377-3968 AU - Karp, Joel S AU - Surti, Suleman AB - In PET imaging Noise Equivalent Counts (NEC) is a common image quality index, derived to be proportional to image SNR 2 and used as an index of general system performance. Many studies have shown that TOF information leads to reduced noise, faster image convergence, and improved SNR. However, the original NEC formula does not account for any contribution of timing resolution to the final image quality, and modified versions of the formula have been proposed to account for the reduction in noise variance and increased sensitivity due to TOF information. In this study, we aim to investigate the relationship between NEC and image SNR in uniform phantoms when OSEM and TOF OSEM image reconstruction is applied. Two cylindrical uniform phantoms, 20 and 35 cm in diameter, were acquired over a wide range of activity levels on a Philips Gemini TF PET scanner. Multiple realizations of the original scans were obtained through bootstrapping and reconstructed with OSEM and TOF OSEM algorithms to obtain mean and standard deviation images. The ratio of the mean value in a central ROI over both images was taken as a measure of image SNR. NEC was calculated from the original data using both the classical and a TOF-adapted formula. The results show that Trues have a better proportionality with image SNR 2 than NEC and TOF NEC in the considered range of activities. Timing resolution and Random fraction appear to have a limited influence on image SNR, but the usage of a matched TOF kernel in reconstruction is found to be necessary to maximize the gain. ER -Download RIS file
00000nam^a2200301^i^4500 | |||
001 | 2940987 | ||
005 | 20180813141936.0 | ||
008 | 120628s2011------------------------eng-- | ||
020 | a 9781467301183 | ||
022 | a 1082-3654 | ||
024 | a 000304755604031 2 wos | ||
024 | a 1854/LU-2940987 2 handle | ||
024 | a 10.1109/NSSMIC.2011.6153744 2 doi | ||
040 | a UGent | ||
245 | a Evaluation of image signal-to-noise ratio in time-of-flight PET | ||
260 | a Piscataway, NJ, USA b IEEE c 2011 | ||
520 | a In PET imaging Noise Equivalent Counts (NEC) is a common image quality index, derived to be proportional to image SNR 2 and used as an index of general system performance. Many studies have shown that TOF information leads to reduced noise, faster image convergence, and improved SNR. However, the original NEC formula does not account for any contribution of timing resolution to the final image quality, and modified versions of the formula have been proposed to account for the reduction in noise variance and increased sensitivity due to TOF information. In this study, we aim to investigate the relationship between NEC and image SNR in uniform phantoms when OSEM and TOF OSEM image reconstruction is applied. Two cylindrical uniform phantoms, 20 and 35 cm in diameter, were acquired over a wide range of activity levels on a Philips Gemini TF PET scanner. Multiple realizations of the original scans were obtained through bootstrapping and reconstructed with OSEM and TOF OSEM algorithms to obtain mean and standard deviation images. The ratio of the mean value in a central ROI over both images was taken as a measure of image SNR. NEC was calculated from the original data using both the classical and a TOF-adapted formula. The results show that Trues have a better proportionality with image SNR 2 than NEC and TOF NEC in the considered range of activities. Timing resolution and Random fraction appear to have a limited influence on image SNR, but the usage of a matched TOF kernel in reconstruction is found to be necessary to maximize the gain. | ||
598 | a P1 | ||
700 | a Clementel, Enrico u TW06 0 000070817575 0 802000402786 9 FA9F103E-F0ED-11E1-A9DE-61C894A0A6B4 | ||
700 | a Vandenberghe, Stefaan u TW06 0 801001340071 0 0000-0002-2377-3968 9 F5BEDD1A-F0ED-11E1-A9DE-61C894A0A6B4 | ||
700 | a Karp, Joel S | ||
700 | a Surti, Suleman | ||
650 | a Medicine and Health Sciences | ||
653 | a SCANNER | ||
653 | a BENEFIT | ||
653 | a IMPACT | ||
773 | t 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2011) g 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (SS/MIC 2011). 2011. IEEE. p.3917-3921 q :<3917 | ||
856 | 3 Full Text u https://biblio.ugent.be/publication/2940987/file/2941004 z [open] y Evaluation_of_Image_Signal-to-Noise_Ration_in_TOF_PET.pdf | ||
920 | a confcontrib | ||
Z30 | x EA 1 TW06 | ||
922 | a UGENT-EA | ||
Z30 | x IB 1 IBBT | ||
922 | a UGENT-EA |
All data below are available with an Open Data Commons Open Database License. You are free to copy, distribute and use the database; to produce works from the database; to modify, transform and build upon the database. As long as you attribute the data sets to the source, publish your adapted database with ODbL license, and keep the dataset open (don't use technical measures such as DRM to restrict access to the database).
The datasets are also available as weekly exports.